DISPLAY
Hewlett-Packard
Hexadecimal Dis
-
YES
Hexadecimal and Numeric
Indicators
Technical Data
5082-7300
5082-7302
5082-7304
5082-7340
Features
• Numeric 5082-7300/-7302
0-9, Test State, Minus Sign,
Blank States
Decimal Point
7300 Right Hand D.P.
7302 Left Hand D.P.
• Hexadecimal 5082-7340
0-9, A-F, Base 16 Operation
Blanking Control, Conserves
Power
No Decimal Point
• DTL/TTL Compatible
• Includes Decoder/Driver with
5-Bit Memory
8421 Positive Logic Input
• 4 x 7 Dot Matrix Array
Shaped Character, Excellent
Readability
• Standard Dual-in-Line
Package Including Contrast
Filter
15.2 mm x 10.2 mm (0.6 inch
x 0.4 inch)
• Categorized for Luminous
Intensity
Assures Uniformity of Light
Output from Unit to Unit
within a Single Category
Description
Agilent’s 5082-7300 series solid
state numeric and hexadecimal
indicators with on-board decoder/
driver and memory provide 7.4 mm
(0.29 inch) displays for reliable,
low-cost methods of displaying
digital information.
The 5082-7300 numeric indicator
decodes positive 8421 BCD logic
inputs into characters 0-9, a “–”
sign, a test pattern, and four
blanks in the invalid BCD states.
The unit employs a right-hand
decimal point.
Package Dimensions
FUNCTION
5082-7300
and 7302
NUMERIC
5082-7340
HEXADECIMAL
PIN
1
2
3
4
INPUT 2
INPUT 4
INPUT 8
INPUT 2
INPUT 4
INPUT 8
BLANKING
CONTROL
NOTES:
1. DIMENSIONS IN MILLIMETERS
AND (INCHES).
2. UNLESS OTHERWISE SPECIFIED,
THE TOLERANCE ON ALL
DIMENSIONS IS ± 0.38 mm
(± 0.015 INCH).
3. DIGIT CENTER LINE IS ± 0.25 mm
(± 0.01 INCH) FROM PACKAGE
CENTER LINE.
GROUND
V
CC
INPUT 1
LATCH
ENABLE
5
6
7
8
GROUND
V
CC
INPUT 1
LATCH
ENABLE
DECIMAL
POINT
14.0
(0.55)
10.2 MAX.
(0.400)
4.8
(0.19)
7.4
(0.29)
1.5
(0.06)
5082-7300
14.0
(0.55)
10.2 MAX.
(0.400)
4.8
(0.19)
7.4
(0.29)
1.5
(0.06)
5082-7302
14.0
(0.55)
10.2 MAX.
(0.400)
4.8
(0.19)
7.4
(0.29)
1.5
(0.06)
5082-7340
3.0
(0.12)
5.6
(0.22)
5.6
(0.22)
3.6
(0.14)
10.2
(0.400)
5082
7300
YYWW
X
LUMINOUS
INTENSITY
CATEGORY
DATE CODE
PIN 1 KEY
5678
4321
15.2
(0.600)
4.3
(0.17)
2.8
(0.11)
0.3 ± 0.08 TYP.
(0.012 ± 0.003)
0-10°
SEATING
PLANE
3.4
(0.135)
2.5 ± 0.13 TYP.
(0.10 ± 0.005)
3.8
(0.15)
1.3 TYP.
(0.050)
1.5
(0.06)
SEATING
PLANE
0.5 ± 0.08 TYP.
(0.020 ± 0.003)
2
The 5082-7302 is the same as the
5082-7300, except that the
decimal point is located on the left-
hand side of the digit.
The 5082-7340 hexadecimal
indicator decodes positive 8421
logic inputs into 16 states, 0-9 and
A-F. In place of the decimal point
an input is provided for blanking
the display (all LEDs off), without
losing the contents of the memory.
Applications include terminals and
computer systems using the base-
16 character set.
The 5082-7304 is a (± 1)
overrange display including a right-
hand decimal point.
Applications
Typical applications include point-
of-sale terminals, instrumentation,
and computer systems.
Absolute Maximum Ratings
Description Symbol Min. Max. Unit
Storage Temperature, Ambient T
S
-40 +100 °C
Operating Temperature, Case T
C
-20 +85 °C
V
CC
Pin Potential to Ground Pin V
CC
-0.5 +7.0 V
Voltage Applied to Input Logic Pins and Decimal Point
[1]
Voltage Applied to Latch Enable V
E
-0.5 +5.5 V
Voltage Applied to Blanking Control
[2]
V
B
-0.5 +5.5 V
Notes:
1. Decimal point applies only to 7300/7302.
2. Applies only to 7340.
Recommended Operating Conditions
Description Symbol Min. Nom. Max. Unit
Supply Voltage V
CC
4.5 5.0 5.5 V
Logic Voltage “0” State V
IN(0)
0 0.8 V
Logic Voltage “1” State V
IN(1)
2.0 5.25 V
Latch Enable Voltage – Data Being Entered V
E(0)
0 0.8 V
Latch Enable Voltage – Data Not Being Entered V
E(1)
2.0 5.25 V
Blanking Control Voltage – Display Not Blanked
[1]
V
B(0)
0 0.8 V
Blanking Control Voltage – Display Blanked
[1]
V
B(1)
3.5 5.25 V
Note:
1. Applies only to 7340.
3
Electrical/Optical Characteristics (T
A
= -20°C to +85°C, Unless Otherwise Specified)
Description Symbol Test Conditions Min. Typ. Max. Unit
Supply Current I
CC
V
CC
= 5.5 V 94
[1]
170
[2]
mA
Power Dissipation P
T
V
CC
= 5.5 V 470
[1]
935
[2]
mW
Luminous Intensity per LED I
V
V
CC
= 5.5 V, T
C
= 25°C3270 µcd
(Digit Average)
[3]
Minimum Time Data Must Be t
SETUP
V
CC
= 5.0 V, V
E(0)
= 0.4 V 30 50 ns
Presented to Logic Input Prior V
IN(0)
= 0.4 V, V
E(1)
= 2.4 V
to Enable Rising V
IN(1)
= 2.4 V, T
C
= 25°C
Minimum Time Data Must Be t
HOLD
V
CC
= 5.0 V, V
E(0)
= 0.4 V 30 50 ns
Held After Enable Rises V
IN(0)
= 0.4 V, V
E(1)
= 2.4 V
V
IN(1)
= 2.4 V, T
C
= 25°C
Time Required for 90% Change t
BLANK
V
CC
= 5.0 V, T
C
= 25°C 500 ns
in Display Luminous Intensity
After Change of State of F
B
[4]
Blanking Control Current “0” State
[4]
I
B(0)
V
CC
= 5.5 V, V
B(0)
= 0.8 V 200 µA
Blanking Control Current “1” State
[4]
I
B(1)
V
CC
= 5.5 V, V
B(1)
= 4.5 V 2.0 mA
Logic and Latch Enable I
IN(0)
,V
CC
= 5.5 V -1.6 mA
Currents “0” State I
E(0)
V
IN
, V
E
= 0.4 V
Logic and Latch Enable I
IN(1)
,V
CC
= 5.5 V +250 µA
Currents “1” State I
E(1)
V
IN
, V
E
= 2.4 V
Peak Wavelength λ
PEAK
T
C
= 25°C 655 nm
Spectral Halfwidth ∆λ
1/2
T
C
= 25°C30nm
Weight 0.8 gm
Notes:
1. V
CC
= 5.0 V with statistical average number of LEDs lit.
2. Worst case condition excluding test state on 5082-7300/-7302.
3. The digits are categorized for luminous intensity such that the variation from digit to digit within a category is not discernible to the
eye Intensity categories are designated by a letter located on the reverse side of the package contiguous with the Agilent logo
marking.
4. Applies only to -7340.
Truth Table for 5082-7300 Series Devices
Character Input Character Inputs
5082- 5082- 5082- 5082-
7300/7302 7340 7300/7302 7340
Numeric Hex. X8 X4 X2 X1 E B
[1]
Numeric Hex. X8 X4 X2 X1 E B
[1]
0 0 L L L L L Test A H L H L L L
1 1 L L L H L L Blank B H L H H L L
2 2 L L H H L L Minus D H H L H L L
3 3 L L H H L L Minus D H H L H L L
4 4 L H L L L L Blank E H H H L L L
5 5 L H L H L L Blank F H H H H L L
6 6 L H H L L L Hold Hold d d d d H d
7 7 L H H H L L Blank
[1]
d d dddH
8 8 H L L L L L Decimal pt. on
[2]
–DP
IN
= L
9 9 H L L H L L Decimal pt. off
[2]
–DP
IN
= H
Notes:
1. The blanking control input, B, pertains to the 5082-7340 Hexadecimal Indicator only.
2. The decimal point input pertains to the 5082-7300 and -7302 Numeric Indicators only.
3. H = logic ‘1’; L = logic ‘0’; d = ‘don’t care.’

Analog Devices Inc.
IC SEQUENCER/SUPERVISOR 32LQFP
Texas Instruments
IC ADC 16BIT SAR 10VSSOP
CUI Devices
24 VDC 5 A Vertical Through Hole Male 2 Position Power Jack
STMicroelectronics
BTA10 Series 600 V 10 A Flange Mount Snubberless Triac - TO-220AB
Bulgin
48 V 2 A SPST-NO Off-Mom Standard Panel Mount, Front Pushbutton Switch
Nexperia
PBSS4540Z Series 40 V 5 A 2 W NPN SMT Small Signal Transistor - SOT-223
Bulgin
Fiber Optic Connectors No Cable Rear panel mount fiber conn
Bulgin
Fiber Optic Connectors No Cable Rear panel mount fiber conn
Bulgin
Fuse Holder PANEL MNT FUSE HLDR 5 x 20mm
Bulgin
Fuse Holder IN-LINE FUSE HLDR 5X20mm
Bulgin
Fuse Holder SEALED PNL MNT FUSE HLDR 5 x 20mm
STMicroelectronics
SCRs 20 A 600 V High Temperature SCR in TO-220I
Microchip Technology / Atmel
EEPLD - Electronically Erasable Programmable Logic Devices 500 Gate SPLD 5V 24pin
Littelfuse
Triacs ISO TO220 16A 10MA TRIAC
CTS Electronic Components
Encoders 20mm Optical Ring Encoder
MEAN WELL
Power Inverters 1200W 230Vac12V 120A AU Socket
Murata Electronics
FIXED IND 56NH 200MA 820MOHM SMD
Murata
BLM Series 0402 600 Ohm 100 mA 0.85 Ohm DCR Surface Mount Ferrite Bead
Laird Technologies Inc
Hewlett-Packard
Hexadecimal Display LED Red8Pin Dip
关闭
Inquiry
captcha

15815509278

295144934@qq.com
0