ISO 9001 ISO 14001 AS 9100 CERTIFIED
Mini-Circuits
®
P.O. Box 350166, Brooklyn, New York 11235-0003 (718) 934-4500 Fax (718) 332-4661 For detailed performance specs & shopping online see Mini-Circuits web site
The Design Engineers Search Engine Provides ACTUAL Data Instantly From MINI-CIRCUITS At: www.minicircuits.com
minicircuits.com
TM
IF/RF MICROWAVE COMPONENTS
PCB Land Pattern
Suggested Layout,
Frequency
(MHz)
Mainline Loss
(dB)
In-Out
Coupling
(dB)
In-Cpl
Directivity
(dB)
In
Return Loss
(dB)
Out Cpl
Typical Performance Data
Directional Coupler Electrical Specifications
Maximum Ratings
Pin Connections
Features
• wideband, 5 to 200 MHz
• low mainline loss, 1.7 dB typ.
• excellent coupling atness, ±0.1 typ.
• aqueous washable
• protected by U.S Patents 6,133,525 & 6,140,887
Applications
• communications
• cable tv
Operating Temperature -40°C to 85°C
Storage Temperature -55°C to 100°C
CASE STYLE: CD542
PRICE: $7.95 ea. QTY (10-49)
Demo Board MCL P/N: TB-32
Suggested PCB Layout (PL-094)
Outline Drawing
Outline Dimensions ( )
inch
mm
ADC-6-1R
MAINLINE LOSS
1.0
1.2
1.4
1.6
1.8
2.0
0 50 100 150 200
FREQUENCY (MHz)
INSERTION LOSS (dB)
at RF level of -10 dBm
ADC-6-1R
COUPLING & DIRECTIVITY
0
10
20
30
40
50
60
0 50 100 150 200
FREQUENCY (MHz)
(dB)
COUPLING DIRECTIVITY
at RF level of -10 dBm
ADC-6-1R+
ADC-6-1R
ADC-6-1R
RETURN LOSS
15
16
17
18
19
20
0 50 100 150 200
FREQUENCY (MHz)
RETURN LOSS (dB)
IN OUT CPL
at RF level of -10 dBm
50Ω 5 to 200 MHz
Directional Coupler
REV. C
M119986
ED-6746
ADC-6-1R
WZ/TD/CP/AM
081111
Surface Mount
6.91 7.87 5.59 2.54 2.84 1.40 2.54
FREQ.
(MHz)
COUPLING
(dB)
MAINLINE LOSS
1
(dB)
DIRECTIVITY
(dB)
VSWR
(:1)
POWER
INPUT, W
Nom. Flatness
L
Typ. Max.
M
Typ. Max.
U
Typ. Max.
L
Typ. Min.
M
Typ. Min.
U
Typ. Min. Typ.
L MU
Max. Max.
f
L
-f
U
5-200 6.2±0.3 ±0.3 1.6 2.0 1.7 2.0 1.7 2.1 35 22 25 18 17 13 1.33 0.5 0.5
INPUT 1
OUTPUT 6
COUPLED 3
GROUND 2,5
ISOLATE (DO NOT USE) 4
+ RoHS compliant in accordance
with EU Directive (2002/95/EC)
The +Suffix identifies RoHS Compliance. See our web site
for RoHS Compliance methodologies and qualifications.
L= 5-50 MHz M= 50-100 MHz U= 100-200 MHz
1. Mainline loss includes theoretical power loss at coupled port.
5.00 1.60 6.15 43.32 15.12 17.27 17.76
15.00 1.62 6.11 40.58 15.28 17.10 17.61
30.00 1.63 6.14 34.62 15.41 17.08 17.65
50.00 1.59 6.18 30.14 15.52 17.03 17.69
70.00 1.68 6.13 27.21 15.59 16.91 17.69
90.00 1.63 6.19 24.97 15.72 16.82 17.69
110.00 1.63 6.19 23.20 15.84 16.70 17.69
130.00 1.72 6.15 21.73 15.92 16.58 17.71
150.00 1.70 6.17 20.47 16.03 16.47 17.87
220.00 1.78 6.07 17.12 16.38 16.05 17.98
Electrical Schematic