A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
M20S-04230A122, M20E-04230A222 | M2000 RES/EDM
MULTIPLE LIGHT BEAM SAFETY DEVICES
Ordering information
System part Type Part no.
Sender M20S-04230A122 1018182
Receiver M20E-04230A222 1018211
1.) Concerns installation as a replacement part for previous type 2device in machine: Regarding Machinery Directive
2006/42/EC, Article 1,Paragraph (2a) this type 2device may only be used as a replacement part for identical PLd/ SIL2
devices within the EU if the machine was put into circulation before 2015-05-10. Keep this note with your machine documen-
tation. If the machine is sold on, this note and the information it contains must be passed on to every subsequent buyer. 2.)
Concerns installation on new machines: Due to the amendment to the EN/IEC61496-1 standard, this type 2device may only
be installed on new machines up to PL c / SIL1 as of 2015-05-10.
Other models and accessories www.sick.com/M2000_RES_EDM
Detailed technical data
Safety-related parameters
Type
Type 2(IEC61496)
Safety integrity level
SIL1 (IEC61508)
SILCL1 (EN62061)
Category
Category 2(ENISO13849)
Test rate (internal test)
13/s (ENISO13849)
1)
Maximum demand rate
≤ 8min⁻¹ (ENISO13849)
2)
Performance level
PL c (ENISO13849)
PFH
D
(mean probability of a dangerous fail-
ure per hour)
6.6x10
-9
(ENISO13849)
T
M
(mission time)
20years (ENISO13849)
Safe state in the event of a fault
At least one OSSD is in the OFF state.
1)
Internal test. The test rate may not be exceeded if an external test is performed.
2)
Between two requirements on a safety-related response of the device, at least 100internal or external tests must be carried out.
Functions
Functions Delivery status
Restart interlock
✔
Beam coding
✔ Uncoded
Configurable scanning range
✔
Interfaces
System connection
Connection type Male connector M12, 8-pin
Conductor cross-section 0.25mm²
Permitted cable length
≤ 15m
1)
Permitted cross-section ≥0.25mm²
1)
Depending on load, power supply and wire cross-section. The technical specifications must be observed.
2)
For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
2 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-06-14 08:06:28
Subject to change without notice
M20S-04230A122, M20E-04230A222 | M2000 RES/EDM
MULTIPLE LIGHT BEAM SAFETY DEVICES
Configuration method
Hard wired
Display elements
LEDs
7-segment display
Fieldbus, industrial network
Integration via Flexi Soft safety controller
CANopen, DeviceNet™, EtherCAT®, EtherNet/IP™, Modbus TCP, PROFIBUS DP, PROFINET
2)
1)
Depending on load, power supply and wire cross-section. The technical specifications must be observed.
2)
For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
Electrical data
Protection class
III (EN50178)
Supply voltage V
S
24VDC (19.2VDC... 28.8VDC)
1)
Power consumption
≤3.7W (DC)
Safety outputs (OSSD)
Type of output 2PNP semiconductors, short-circuit protected, cross-circuit monitored
1)
The external voltage supply must be capable of buffering brief mains voltage failures of 20ms as specified in EN60204-1. Suitable power supplies are available as
accessories from SICK.
Mechanical data
Housing cross-section
48mmx 40mm
Ambient data
Enclosure rating
IP65 (EN60529)
Ambient operating temperature
0°C... +55°C
Storage temperature
–25°C... +70°C
Air humidity
15%... 95%, Non-condensing
Vibration resistance
5g, 10Hz... 55Hz (IEC60068-2-6)
Shock resistance
10g, 16ms (IEC60068-2-29)
Other information
Wave length
950nm
2017-06-14 08:06:28 | Online data sheet
Subject to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 3